SSH35 – reduction box

The model SSH35 fits perfect for bigger pumps like the XDS-series from Edwards, the Sogevac-series from Leybold, the models MS40+ and MS30+ from Varian and many more bigger vacuum pumps.
To serve the different needs, we offer the SSH35 with 2 or 4 fans and also with IEC 10A or IEC 16A power sockets.


Versions and order codes:

Models with APPS:

SSH35-21U

  • Temperature monitoring with alarm
  • Two temperature controlled fans with speed monitoring
  • IEC 10A (C13) power outlet inside the box with current monitoring and emergency shutdown to power the vacuum pump
  • IEC 10A (C14) power socket to connect the box to your MS or to a wall outlet
  • Wide range input 100-250V AC (50/60 Hz)


SSH35-22U

  • Temperature monitoring with alarm
  • Two temperature controlled fans with speed monitoring
  • IEC 16A (C19) power outlet inside the box with current monitoring and emergency shutdown to power the vacuum pump
  • IEC 16A (C20) power socket to connect the box to your MS or to a wall outlet
  • Wide range input 100-250V AC (50/60 Hz)


SSH35-41U

  • Temperature monitoring with alarm
  • Four temperature controlled fans with speed monitoring
  • IEC 10A (C13) power outlet inside the box with current monitoring and emergency shutdown to power the vacuum pump
  • IEC 10A (C14) power socket to connect the box to your MS or to a wall outlet
  • Wide range input 100-250V AC (50/60 Hz)


SSH35-42U

  • Temperature monitoring with alarm
  • Four temperature controlled fans with speed monitoring
  • IEC 16A (C19) power outlet inside the box with current monitoring and emergency shutdown to power the vacuum pump
  • IEC 16A (C20) power socket to connect the box to your MS or to a wall outlet
  • Wide range input 100-250V AC (50/60 Hz)



Models without APPS:

SSH35-212 (former SSH35TF10A)

  • Two fans for heat removal
  • Connects to 230V AC (50/60Hz) mains
  • IEC 10A (C14) power socket to connect the box to your MS or to a wall outlet
  • IEC 10A (C13) power outlet inside the box to power the vacuum pump


SSH35-222 (former SSH35TF16A)

  • Two fans for heat removal
  • Connects to 230V AC (50/60Hz) mains
  • IEC 16A (C20) power socket to connect the box to your MS or to a wall outlet
  • IEC 16A (C19) power outlet inside the box to power the vacuum pump


SSH35-412 (former SSH35QF10A)

  • Four fans for heat removal
  • Connects to 230V AC (50/60Hz) mains
  • IEC 10A (C14) power socket to connect the box to your MS or to a wall outlet
  • IEC 10A (C13) power outlet inside the box to power the vacuum pump


SSH35-422 (former SSH35QF16A)

  • Four fans for heat removal
  • Connects to 230V AC (50/60Hz) mains
  • IEC 16A (C20) power socket to connect the box to your MS or to a wall outlet
  • IEC 16A (C19) power outlet inside the box to power the vacuum pump


SSH35-211 (former SSH35TF10A-115V)

  • Two fans for heat removal
  • Connects to 115V AC (50/60Hz) mains
  • IEC 10A (C14) power socket to connect the box to your MS or to a wall outlet
  • IEC 10A (C13) power outlet inside the box to power the vacuum pump


SSH35-221 (former SSH35TF16A-115V)

  • Two fans for heat removal
  • Connects to 115V AC (50/60Hz) mains
  • IEC 16A (C20) power socket to connect the box to your MS or to a wall outlet
  • IEC 16A (C19) power outlet inside the box to power the vacuum pump


SSH35-411 (former SSH35QF10A-115V)

  • Four fans for heat removal
  • Connects to 115V AC (50/60Hz) mains
  • IEC 10A (C14) power socket to connect the box to your MS or to a wall outlet
  • IEC 10A (C13) power outlet inside the box to power the vacuum pump


SSH35-421 (former SSH35QF16A-115V)

  • Four fans for heat removal
  • Connects to 115V AC (50/60Hz) mains
  • IEC 16A (C20) power socket to connect the box to your MS or to a wall outlet
  • IEC 16A (C19) power outlet inside the box to power the vacuum pump
Contact us if you want to know more about SSH35 – reduction box